
Use the best ways of preparing for 5V0-21.21 Exam Dumps with ValidExam VMware 5V0-21.21 dump PDF [2021]
VMware 5V0-21.21 exam candidates will surely pass the Exam if they consider the 5V0-21.21 dumps learning material presented by ValidExam.
NEW QUESTION 15
An administrator has an absent capacity disk.
Which action, if any, should the administrator take to resolve the problem?
- A. Wait, and vSAN will rebuild it.
- B. Replace the faulty disk.
- C. Verify the host is not isolated.
- D. Replace the faulty host.
Answer: A
NEW QUESTION 16
An administrator of "vsan-prod" cluster noticed the witness components of VMs are flagged as absent after a failed attempt to replace the vSAN Witness Host.
Which action should the administrator take to resolve this issue?
- A. Placing the vSAN Witness Host in Maintenance Mode and adding to the vSAN cluster
- B. Upgrading the vSAN on-disk format
- C. Running the vSAN Skyline Health check to ensure there are vSAN Object Health errors and executing the Repair Object Immediately option
- D. Using the RVC command: vsan.resync_dashboard ~/computers/vsan-prod
Answer: A
NEW QUESTION 17
An administrator is tasked with migrating a VMware Horizon View environment that is currently running on an NFS Datastore to VMware vSAN.
Which Horizon configuration option will not be available when configuring vSAN in Horizon View?
- A. Storage Profiles
- B. Instant Clones
- C. Linked Clones
- D. Storage Tiers
Answer: D
NEW QUESTION 18
Upon investigating a workload performance issue, a vSAN administrator observed a high backend IOPs on a vSAN cluster.
Which two causes explain this behavior? (Choose two.)
- A. The cluster DRS threshold has been set to Aggressive.
- B. There is a vSAN node failure.
- C. The vSAN Resync throttling is enabled.
- D. The object repair timer value has been increased.
- E. The vSAN policy protection level has changed from FTT=0 to FTT=1.
Answer: C,E
NEW QUESTION 19
A 4-node vSAN cluster is configured with an erasure coding storage policy. The Ensure Accessibility maintenance mode was selected. While performing the maintenance, a second node fails.
What will be the impact on the vSAN cluster?
- A. The performance will be degraded.
- B. The VMs will be in a suspended state.
- C. The VMs will no longer be accessible.
- D. There will be no impact on performance.
Answer: D
NEW QUESTION 20
In a vSAN stretched cluster, which value must be set in the vSAN policy if there is no requirement for data mirroring across sites?
- A. PFTT = 0
- B. SFTT = 1
- C. PFTT = 1
- D. SFTT = 0
Answer: D
NEW QUESTION 21
During a vSAN design workshop, an architect collected these customer requirements:
* Leverage vSAN storage policies with Erasure Coding.
* Enable Deduplication and Compression.
* Use the minimum number of hosts in the cluster.
* Maintain full storage policy compliance when two nodes are down.
Which vSAN cluster design meets the customer's requirements?
- A. Five nodes Hybrid vSAN cluster
- B. Five nodes All-Flash vSAN cluster
- C. Six nodes All-Flash vSAN cluster
- D. Six nodes Hybrid vSAN cluster
Answer: C
NEW QUESTION 22
An administrator wants to deploy Kubernetes on an end-to-end VMware stack, using VMware vSAN for storage.
Which VMware product should the administrator install as the Kubernetes platform choice?
- A. VMware Tanzu Kubernetes Grid
- B. VMware Tanzu Build service
- C. VMware Tanzu Mission Control
- D. VMware Tanzu Data services
Answer: A
NEW QUESTION 23
An administrator has been tasked to reboot a node in an encrypted vSAN cluster. The vSAN disk groups on that node become locked after rebooting the node.
Which step should be performed to exit the locked state?
- A. Manually replace the Host Encryption Key (HEK) of each affected host.
- B. Run /etc/init.d/vsanvpd restart to rescan the VASA providers.
- C. Restore the communication with the KMS server, and re-establish the trust relationship.
- D. Replace the caching device in each affected disk group.
Answer: C
NEW QUESTION 24
During a maintenance action on a vSAN node, a vSAN administrator noticed that the default repair delay time is about to be reached.
Which two commands must be run to extend the time? (Choose two.)
- A. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 50
- B. /etc/init.d/clomd restart
- C. /etc/init.d/vsanmgmtd restart
- D. /etc/init.d/vsanobserver restart
- E. esxcli system settings advanced set -o /VSAN/ClomRepairDelay -i 80
Answer: B,E
NEW QUESTION 25
A 30-minute power maintenance window has been approved on Sunday. Due to a delay, the maintenance took 20 minutes longer to finish.
During this time, the vSAN administrator noticed that one of the clusters nodes was affected by a power shortage, as it was connected to an affected power source. The default vSAN storage policy has been applied.
What will be the status of the vSAN objects on the affected host immediately after it is recovered?
- A. A rebuild of the affected objects will occur.
- B. The cluster will be partitioned and the vSAN host will need to be rejoined.
- C. All objects will remain accessible.
- D. All objects on the affected host will be lost.
Answer: A
NEW QUESTION 26
A customer is planning to deploy a vSAN cluster to host their in-house distributed ERP system. The hardware specifications for their server nodes include:
* 2 x Intel Xeon CPU E5-2697 v3 @ 2.60GHz
* 1TB memory
Which boot device is supported for the vSAN ESXi nodes for this customer?
- A. A 16GB single-level cell (SLC) SATADOM device must be used.
- B. A 4GB USB or SD device must be used.
- C. ESXi Hosts must boot from a PMEM device.
- D. A 16GB multiple-level cell (MLC) SATADOM device must be used.
Answer: D
NEW QUESTION 27
An administrator managing a vSAN cluster of six-nodes with policy FTT-2/RAID-6 decided to put one of the nodes in maintenance mode using the "Full-data migration" option.
What will happen after this action is taken?
- A. The host will enter in maintenance mode and only data with no redundancy will remain accessible.
- B. The system will prompt to add an additional host to the cluster in order to preserve the policy compliance.
- C. The host will enter into maintenance mode if both components of a certain object are residing on that host, then one of the components will be moved to another available host.
- D. The host will enter in maintenance mode and the data will remain accessible until the host exits maintenance mode.
Answer: D
NEW QUESTION 28
In a stretched vSAN cluster, how is Read Locality established after fail over to the secondary site?
- A. 100% of the reads comes from vSAN hosts on the remote site
- B. 50% of the reads comes from vSAN hosts on the remote site
- C. 100% of the reads comes from vSAN hosts on the local site
- D. 50% of the reads comes from vSAN hosts on the local site
Answer: C
NEW QUESTION 29
An architect needs to automate an infrastructure that supports VMware Horizon as well as VMware Tanzu.
Which solution mandates the use of VMware vSAN?
- A. VMware vRealize Automation
- B. VMware Cloud Foundation
- C. VMware Horizon
- D. VMware Tanzu
Answer: A
NEW QUESTION 30
An administrator is planning to deploy workloads on a six node vSAN cluster, and all nodes are distributed equally across three racks.
Which action is required to ensure that the workload VMs remain compliant with the default vSAN policy after a complete rack failure?
- A. Add an additional rack with two hosts, and configure vSAN with four fault domains and FTT=1 (mirroring).
- B. Add an additional rack with two hosts, and configure vSAN with four fault domains and FTT=1 (erasure coding).
- C. Add an additional host per rack, and configure vSAN with three fault domains and FTT=2.
- D. Add two additional hosts per rack, and configure vSAN with three fault domains and FTT=1.
Answer: A
NEW QUESTION 31
During a design workshop for a stretched vSAN cluster, the requirement that some of the VMs be configured with no-mirror between sites was discussed.
Which three recommendations should the architect provide to address an event of a network partition between two sites? (Choose three.)
- A. The default gateway must be used as the only isolation address
- B. One of isolation addresses should reside in the site 1 data center
- C. One isolation address reachable only from the witness appliance in both sites
- D. VMware vSphere DRS rules to force the VMs to run where the data resides
- E. One of isolation addresses should reside in the site 2 data center
- F. Host isolation response must exclude the VMs required
Answer: D,E,F
NEW QUESTION 32
A company has deployed a 12-node (6-6-1) vSAN 7.0 stretched cluster for all production workloads.
The customer currently uses four different vSAN storage policies for running the workloads depending on the applications requirements:
* Policy 1 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Erasure Coding
* Policy 2 - Site Disaster Tolerance=Dual Site Mirroring, FTT=Mirroring
* Policy 3 - Site Disaster Tolerance=None - Keep Data on Preferred, FTT=Mirroring
* Policy 4 - Site Disaster Tolerance=None - Keep Data on Non-Preferred, FTT=Mirroring During the setup of the vSAN stretched cluster, the following VM/Host Rules were created:
* Preferred Site - Preferred Site workloads should run on DC1 hosts.
* Secondary Site - Secondary Site workloads should run on DC2 hosts.
Which two activities should the administrator complete to ensure that there is no impact to production services during the maintenance window in the Preferred Site? (Choose two.)
- A. Change the Site Disaster Tolerance setting in Policy 3 to be "Dual Site Mirroring".
- B. Update vSphere DRS site affinity rules so that Preferred Site workloads must run on hosts in DC2.
- C. Change the Site Disaster Tolerance setting in Policy 4 to be "None - Keep Data on Preferred".
- D. Update vSphere DRS site affinity rules so that Preferred Site workloads should not run on hosts in DC1.
- E. Change the FTT setting in Policy 3 to be "Erasure Coding".
Answer: B,C
NEW QUESTION 33
An administrator wants to enable encryption on an existing vSAN cluster that already contains virtual machines.
Which additional step should the administrator take to ensure no data is lost during the encryption process?
- A. Make vCenter Server trust the KMS, either by trusting the KMS or by uploading a KMS certificate.
- B. Select 'Erase disks before use' check box when enabling encryption on a vSAN cluster.
- C. Disable vSphere Distributed Resources Schedule (DRS) on the vSAN cluster.
- D. Ensure that the vSAN Encryption is enabled by default on the existing cluster to encrypt old and new data.
Answer: B
NEW QUESTION 34
A company hosts a vSAN 7 stretched cluster for all development workloads. The original sizing of a maximum of 250 concurrent workloads in the vSAN cluster is no longer sufficient and needs to increase to at least 500 concurrent workloads within the next six months.
To meet this demand, the original 8-node (4-4-1) cluster has recently been expanded to 16 nodes (8-8-1).
Which three additional steps should the administrator take to support the current growth plans while minimizing the amount of resources required at the witness site? (Choose three.)
- A. Add the new vSAN witness appliance to vCenter Server.
- B. Configure the new vSAN witness as a shared witness appliance.
- C. Deploy a new extra large vSAN witness appliance at the witness site.
- D. Upgrade the vSAN stretched cluster to vSAN 7.0 U1.
- E. Configure the vSAN stretched cluster to use the new vSAN witness.
- F. Deploy a new large vSAN witness appliance at the witness site.
Answer: B,E,F
NEW QUESTION 35
......
Full 5V0-21.21 Practice Test and 52 unique questions with explanations waiting just for you, get it now: https://drive.google.com/open?id=1NLVfjptPfFCL0bnW7XUA93ZiToX1GJ5g
Accurate & Verified Answers As Seen in the Real Exam here: https://www.validexam.com/5V0-21.21-latest-dumps.html