Try Before You Buy

Download a free sample of any of our exam questions and answers

  • 24/7 customer support, Secure shopping site
  • Free One year updates to match real exam scenarios
  • If you failed your exam after buying our products we will refund the full amount back to you.

[Jun-2024] The Best Oracle Utilities Customer Cloud 1z0-996-22 Professional Exam Questions [Q29-Q47]

Share

[Jun-2024] The Best Oracle Utilities Customer Cloud 1z0-996-22 Professional Exam Questions

Try 100% Updated 1z0-996-22 Exam Questions [2024]


Oracle 1z0-996-22 (Oracle Utilities Customer Cloud Service 2022 Implementation Professional) is a certification exam for IT professionals who want to prove their expertise in implementing and managing Oracle Utilities Customer Cloud Service. 1z0-996-22 exam tests the candidate's knowledge of cloud computing, customer service, and utility industry best practices. Passing this certification exam validates the candidate's skills and knowledge in implementing Oracle Utilities Customer Cloud Service.

 

NEW QUESTION # 29
What can cause a bill segment to have multiple bill calculation headers?

  • A. proration at Calculation Rules level
  • B. proration at Bill Factor level
  • C. multiple service agreements being covered by a bill segment
  • D. multiple Scheduled Read Dates covered by the bill period
  • E. multiple Rate Version Calculation Group

Answer: B


NEW QUESTION # 30
Which three are important Account concepts that must always be followed? (Choose three.)

  • A. Bills are produced for an account and are sent to the account persons.
  • B. An Account references one or more persons.
  • C. Every Account has a unique, system-assigned Account ID.
  • D. An Account can only reference one and only one person at one time.
  • E. Accounts expire when there are no active contracts.

Answer: A,B,C

Explanation:
Based on the information available from Oracle Utilities Customer Cloud Service documentation, the three important account concepts that must always be followed are:
Every Account has a unique, system-assigned Account ID (Option C): This is a fundamental concept in Oracle Utilities Customer Cloud Service, ensuring that each account is uniquely identifiable and can be tracked and managed efficiently.
Bills are produced for an account and are sent to the account persons (Option D): This is a key operational concept in the utility services domain. The billing process is centralized around the account, and the bills generated are associated with the account, which in turn is linked to the person or persons responsible for it.
An Account references one or more persons (Option E): This concept is essential in the management of customer information, where an account can be linked to one or more persons, indicating who is responsible or associated with the account.


NEW QUESTION # 31
Approval Profiles control which aspects of an Adjustment?

  • A. control how adjustments are approved
  • B. if an adjustment requires approval before it's frozen
  • C. whether current and/or payoff balance are affected by the adjustment
  • D. whether the adjustment shouldappear on the customer's next bill
  • E. information defaulted on an Adjustment

Answer: A

Explanation:
Approval Profiles in Oracle Utilities Customer Cloud Service play a crucial role in the management and control of adjustments. Specifically, they are responsible for the following aspects:
Control how adjustments are approved (Option B): Approval Profiles define the rules and processes that dictate how an adjustment is to be approved. They establish the parameters and criteria under which an adjustment will undergo the approval process, such as the required levels of approval and the roles or individuals who are authorized to approve the adjustment


NEW QUESTION # 32
When creating a new business object for a service point (SP), what items are required to be able toview and update the new elements associated with the SP?

  • A. Maintenance Object, Application Service, and Schema
  • B. Display UI Map, Display Map Service Script, and Maintenance UI Map
  • C. Validation Algorithm, Post Processing Algorithm, and Lifecycle
  • D. Schema, Validation Algorithm, and Maintenance UI Map

Answer: B

Explanation:
When creating a new business object for a service point in Oracle Utilities Customer Cloud Service, it is necessary to have certain elements in place to view and update the new elements associated with the service point. The correct option, "C. Display UI Map, Display Map Service Script, and Maintenance UI Map", encompasses the essential components for this process.
Display UI Map: The User Interface (UI) Map is crucial for defining how the data fields of the business object are displayed in the user interface. It is essentially a layout that dictates how information is presented and interacted with within the system.
Display Map Service Script: Service Scripts are used to handle the business logic associated with a business object. In the context of a Display Map, the Service Script would be responsible for managing how data is retrieved, manipulated, and presented in the UI, based on the definitions in the UI Map.
Maintenance UI Map: Similar to the Display UI Map, the Maintenance UI Map is focused on the aspects of editing or updating the business object. This UI Map would define how the user interface should be laid out for maintenance tasks, such as updating service point details or adding new information.
These components work together to ensure that when a new business object is introduced for a service point, it can be effectively displayed, maintained, and interacted with within the Oracle Utilities Customer Cloud Service system.
References:
Oracle documentation on Defining Business Objects: Defining Business Objects.
Oracle documentation on Useful Services and Business Services: Useful Services and Business Services.
Oracle documentation on Business Objects: Business Objects.
Oracle documentation on Granting Access To Business Objects: Granting Access To Business Objects.


NEW QUESTION # 33
Which three statements are correct for Adjustment Types? (Choose three.)

  • A. They control the valid Service Agreement Types that adjustments can be linked to.
  • B. They control how adjustments appear on bills.
  • C. They control whether a rate is to be called to calculate an adjustment amount.
  • D. They control the valid Adjustment Profiles that adjustment types can belong to.
  • E. They can default an Adjustment Amount to adjustments.

Answer: B,C,E

Explanation:
Adjustment Types in the Oracle Utilities Customer Cloud Service play a significant role in managing financial transactions, particularly adjustments. Here's a breakdown of the correct statements:
They can default an Adjustment Amount to adjustments (Option A): Adjustment Types can have predefined adjustment amounts. When an adjustment type is selected, the predefined amount can automatically be set as the adjustment amount.
They control how adjustments appear on bills (Option B): The appearance of adjustments on bills, including how they are described and categorized, is governed by the Adjustment Types. This includes the presentation and grouping of these adjustments in the billing statements.
They control whether a rate is to be called to calculate an adjustment amount (Option C): Adjustment Types can determine whether a specific rate needs to be invoked for the calculation of the adjustment amount. This aspect is crucial when the adjustment amount depends on particular rate calculations.
Options D and E, pertaining to the control over Service Agreement Types and Adjustment Profiles, are not directly controlled by Adjustment Types. Instead, these aspects are managed by different configurations within the Oracle Utilities Customer Cloud Service.
References:
Oracle documentation on Designing And Defining Adjustment Types: Designing And Defining Adjustment Types.
Oracle documentation on Setting Up Adjustment Types: Setting Up Adjustment Types.
Oracle documentation on Adjustment Types: Adjustment Types.


NEW QUESTION # 34
You are configuring a VEE group to include rules to be executed when loading the initial measurement data (IMD).
What is the VEE group directly associated with?

  • A. Device Type
  • B. Usage Type
  • C. Device Type and Measuring Component Type
  • D. Device Configuration Type
  • E. Measuring Component Type

Answer: E


NEW QUESTION # 35
A Service Order Orchestrator determines the steps required to complete the service.
As an example, based on the state of the service point, what does the Enable Service Orchestrator determine theactions for?

  • A. Create a Service Point; Install a Device; Turn on the Device
  • B. Create a Device Configuration; Install a Device; Turn on the Device
  • C. Connect the Service Point;Install a Device; Turn on the Device
  • D. Connect the Service Point; Install a Device; Create a Usage Subscription

Answer: C

Explanation:
The Enable Service Orchestrator is a service order orchestrator that determines the steps required to complete the service of enabling service for a customer. The Enable Service Orchestrator uses the state of the service point and the device to decide what actions need to be performed. For example, if the service point is disconnected and the device is not installed, the Enable Service Orchestrator will determine that the following actions are needed: Connect the Service Point; Install a Device; Turn on the Device. These actions will be executed by the corresponding service order activities, such as Connect SP, Install Device, and Turn On Device. References: Oracle Utilities Customer Cloud Service Service Order Configuration Guide, Oracle Utilities Customer Cloud Service Service Order User Guide, Oracle Utilities Customer Cloud Service Service Order Orchestrator Configuration Guide


NEW QUESTION # 36
How many devices can be installed at a service point at an instance in time?

  • A. one for each service type
  • B. exactly one device
  • C. up to three devices
  • D. one for each measuring component

Answer: B


NEW QUESTION # 37
On which three entities can proration be disabled? (Choose three.)

  • A. Rate Version Calculation Group
  • B. Bill Factor
  • C. Calculation Rule
  • D. Calculation Rule Business Object
  • E. Rate Schedule

Answer: A,D,E


NEW QUESTION # 38
Your client has three requirements:
1. Apply validations on meter reads coming from the Data Collectors.
2. If a meter read does not pass the validation, an error will be generated and assigned to a user.
3. Retry the validation every 30minutes for the errors in case the issue is related to configuration.
Which statement describes the base functions you should use?

  • A. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-CRE-IMDTD (Create To Do)
  • B. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, and then processed by the algorithm D1-IMD-RETRY (Retry Initial Measurement Data Processing)
  • C. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be loaded after 30 minutes.
  • D. If a To Do entry is created on the VEE exception, the user will need to discard the IMD and a new IMD will be manually loaded.
  • E. If a To Do entry is created on the VEE exception, the IMD's Next Retry Date/Time is set to 30 minutes, andthen processedby the algorithm D1-COMP-TD (Complete To Do Entries).

Answer: B

Explanation:
The base functions that you should use to meet your client's requirements are the following:
Apply validations on meter reads coming from the Data Collectors: You can use the Oracle Utilities Meter Data Management (MDM) Cloud Service to perform validation, editing, and estimation (VEE) on the initial measurement data (IMD) that is loaded from the Head End system or other source. MDM has a set of predefined VEE rules that can be configured and customized to check the accuracy and completeness of the meter reads. You can also define your own VEE rules using the VEE Rule Maintenance feature. MDM applies the VEE rules to the IMD based on the VEE Group and the VEE Execution Type that are associated with the device configuration and the service point. MDM also supports manual VEE for users to review and edit the IMD.
If a meter read does not pass the validation, an error will be generated and assigned to a user: You can use the To Do feature to create and assign tasks for users to resolve the VEE exceptions that are generated when the IMD fails the validation. You can configure the system to automatically create a To Do entry for each VEE exception or for a group of VEE exceptions based on the To Do Creation Algorithm on the VEE Rule. You can also specify the To Do Type, the To Do Status, the To Do Priority, and the To Do Assignee for the To Do entry. The To Do entry will contain the details of the VEE exception, such as the IMD ID, the VEE Rule ID, the VEE Group ID, and the VEE Execution Type ID. The user can access the To Do entry from the To Do List or the 360 Degree View device portal and take the appropriate action to correct the IMD or the VEE rule.
Retry the validation every 30 minutes for the errors in case the issue is related to configuration: You can use the IMD Retry feature to automatically reprocess the IMD that has VEE exceptions after a specified interval. You can configure the system to set the Next Retry Date/Time on the IMD to 30 minutes after the VEE exception is generated. You can also specify the Maximum Number of Retries and the Retry Interval Algorithm on the VEE Rule. The system will run the algorithm D1-IMD-RETRY (Retry Initial Measurement Data Processing) periodically to identify the IMD that has a Next Retry Date/Time that is less than or equal to the current date and time. The algorithm will then reapply the VEE rules to the IMD and update the VEE results. If the IMD passes the validation, the VEE exception and the To Do entry will be cleared. If the IMD still fails the validation, the Next Retry Date/Time will be updated and the To Do entry will remain open until the user resolves the issue or the maximum number of retries is reached. References: Oracle Utilities Meter Data Management Overview, VEE Rule Maintenance, [To Do], [IMD Retry]


NEW QUESTION # 39
Which usage rule would be used to retrieve scalar measurements and convert the total from one unitof measure to another?

  • A. A custom set of usage rules must be written.
  • B. Get Scalar Details and Apply Formula
  • C. Get Scalar Details and Math
  • D. Get Scalar Details and Axis Conversion

Answer: B

Explanation:
The Get Scalar Details and Apply Formula usage rule is used to retrieve scalar measurements from the measuring components installed at the usage subscription's service points and apply a formula to the total quantity1. This rule can be used to convert the total from one unit of measure to another by using a factor that has a Factor Class of "Number" and a Factor Type of "Conversion"2. For example, this rule can be used to convert the total consumption from cubic feet to therms by applying a factor that multiplies the cubic feet by a conversion rate2. Therefore, the correct answer is B. Get Scalar Details and Apply Formula. References:
Get Scalar Details and Apply Formula
Configuring Usage Calculation Rules


NEW QUESTION # 40
In addition to sets of procedures, and careful handling instructions for hazardous or delicate materials, what can Specifications include to provide information about assets or other entities?

  • A. Rules
  • B. Attributes
  • C. Conditions
  • D. Specifications

Answer: D


NEW QUESTION # 41
Critical validation rules verify the integrity of the initial measurementdata (IMD). If an implementation needs to add new critical validations, where would you configure them?

  • A. in the schema of the IMD Seeder BO (D1-IMDSeeder)
  • B. as optionson the IMD Seeder BO (D1-IMDSeeder)
  • C. in the pre-processing algorithm of the IMD Seeder BO (Dl-IMDSeeder)
  • D. in the validation algorithm on the IMD Seeder BO (D1-IMDSeeder)
  • E. as new lifecycle algorithms on the IMD Seeder BO (D1-IMDSeeder)

Answer: D

Explanation:
The IMD Seeder BO (D1-IMDSeeder) is used to create and update initial measurement data (IMD) records. It has a system event called "Validation" that specifies the algorithm to perform critical validations on the IMD records. If an implementation needs to add new critical validations, they can either modify the existing algorithm or create a new algorithm and assign it to the "Validation" system event. This way, the new validations will be executed whenever the IMD Seeder BO is invoked. References: Oracle Utilities Customer Cloud Service User Guide, Calculation Rule Validation, Cloud Services Implementation Guide


NEW QUESTION # 42
What contains the details of how a bill was calculated and how it will be printed on a bill?

  • A. Service Agreement
  • B. Rate Schedule
  • C. Calculation Rules
  • D. Bill
  • E. Bill Segments

Answer: E


NEW QUESTION # 43
Your client has the following requirements:
Many customers are installing their own solar electrical generationequipment. When these customers generate more electricity than required for their own use, the surplus can he exported back to the power grid.
In order to measure this generation, we have installed special scalar devices. These devices have separate registers to measure the energy generated (export) and the energy received (import) from the National Grid.
Both reads will be stored in kWh, but the import is subtractive and export is consumptive.
What solution should you choose to configure the measuring component types for these specific requirements?

  • A. Create one new measuring component type for creating two measuring components (one for import and the other for export) that will be linked to one scalar device.
  • B. Create two service points: one for subtractive import and the other for consumptive export.
  • C. Create one new measuring component type for creating a new measuring component that will be linked to two different scalar devices (one for import and the other for export).
  • D. Create two new measuringcomponent types (one for subtractive import and the other for consumptive export) to enable the creation of two measuring components that will be linked to one scalar device.

Answer: D

Explanation:
According to the Oracle Utilities Customer Cloud Service User Guides, measuring component types define the most important properties of a measuring component, such as what it measures, how regularly it measures it, and whether it should be connected to a physical device1. Measuring component types also specify how the measuring component's final measurements should be stored, and whether they are subtractive or consumptive1. In this case, the client needs to measure both the energy imported and exported by the customers who have solar electrical generation equipment. Therefore, the solution is to create two new measuring component types, one for subtractive import and the other for consumptive export, and link them to the same scalar device that has separate registers for both readings. This way, the measuring components can store the measurements in kWh and apply the appropriate sign to indicate the direction of the energy flow2. References:
Understanding Measuring Component Types
Measuring Components


NEW QUESTION # 44
Which option correctly describes the high-level process from loading measurements through calculating usage?

  • A. 1. Load Initial Measurements
    2. Validate, evaluate, and estimate Initial Measurements
    3. Update Initial Measurements
    4. Calculate Usage
  • B. 1. Load Initial Measurements
    2. Validate, edit, and estimate Initial Measurements
    3. Create Final Measurements
    4. Update Initial Measurements
  • C. 1. Load Initial Measurements
    2. Verify, evaluate, and enter Initial Measurements
    3. Create Final Measurements
    4. Calculate Usage
  • D. 1. Load Initial Measurements
    2. Validate, edit, and estimate Initial Measurements
    3. Create Final Measurements
    4. Calculate Usage

Answer: C


NEW QUESTION # 45
At what stage in the initial measurement data (IMD) import process will the application of meter multipliers be performed?

  • A. Critical Validation
  • B. VEE
  • C. Prepare for VEE
  • D. post-VEE

Answer: A


NEW QUESTION # 46
You are configuring a VEE group to include rules to be executed when loading the initial measurement data (IMD).
What is the VEE group directly associated with?

  • A. Device Type
  • B. Usage Type
  • C. Device Type and Measuring Component Type
  • D. Measuring Component Type
  • E. Device Configuration Type

Answer: E


NEW QUESTION # 47
......

1z0-996-22 Exam Questions Get Updated [2024] with Correct Answers: https://www.validexam.com/1z0-996-22-latest-dumps.html

Pass 1z0-996-22 Exam - Real Questions and Answers: https://drive.google.com/open?id=1IKruCWIk0Xn2J3bR9p5b1vbdZVwcfBNM