In Huawei RAID 2.0+, is the description about chunck and extent correct?
- A. chunck is the smallest unit for LUN to apply for space from the storage pool and free up space
- B. The extent is the smallest unit for the storage pool to allocate resources from the hard disk domain
- C. The extent size of different storage pools can be different, but the extent size in the same storage pool is uniform
- D. chunck is the smallest unit of hot data statistics and migration (data migration granularity)
Answer: C
Explanation:
Explanation
Analysis: extent is a fixed-size logical storage space divided on the basis of CKG, the size is adjustable, and it is a hot data system.
The smallest unit of accounting and migration (data migration granularity) is also the smallest unit of applying space and releasing space in the storage pool. Do not The extent of the same storage pool can be different, but the extent of the same storage pool is uniform.
CKG is a logical storage unit composed of CKs from different hard drives in the same DG according to the RAID algorithm.
The smallest unit of resources allocated by the pool from the hard disk domain.
NEW QUESTION 245
In the RHEL 5 operating system, which command is used to mount the sdb5 device in the dev directory to the mnt directory sdb5 directory?
- A. df /dev/sdb5 mnt/sdb5
- B. ln /dev/sdb5 /mnt/sdb5
- C. mount /dev/sdb5 /mnt/sdb5
- D. cat /dev/sdb5 /mmt/sdb5
Answer: C
NEW QUESTION 246
The following statement is wrong: (multiple choice)
- A. Backup cannot solve the recovery of data corruption
- B. Backup can directly take over the business
- C. Backup cannot solve the retrieval of historical data
- D. backup to solve the recovery of data loss
Answer: A,B,C
NEW QUESTION 247
Select the features that are commonly available in High End storage systems.
(Multiple Choice)
- A. Second-level Data Copying
- B. ATA Drive Optimization
- C. SSD Optimization
- D. Global Cache
Answer: A,C,D
NEW QUESTION 248
In the Huawei OceanStor V3 storage system, a customer plans to deploy 3 sets of systems, a set of business systems, to run Oracle database, which requires high random read and write performance; a mail system for daily mail processing; a video system System to save long-term archived videos. When creating LUNs for each system separately, the following about SmartTier policy settings the correct one is? (Multiple choice)
- A. Mail system:
1. Initial capacity allocation: automatic allocation
2. Data migration strategy: automatic migration - B. Business system:
1. Initial capacity allocation: priority allocation from the performance layer
2. Data migration strategy: move to the low-performance layer - C. Video system:
1. Initial capacity allocation: priority allocation from capacity tier
2. Data migration strategy: move to the low-performance layer - D. Video system:
1. Initial capacity allocation: priority allocation from capacity tier
2. Data migration strategy: automatic migration
Answer: A,C
NEW QUESTION 249
In the Huawei OceanStor V3 storage system, which of the following descriptions about mapping snapshot LUNs is correct?
- A. The description of all options is correct
- B. The snapshot LUN mapped to the host can only be read, not written
- C. The activated snapshot LUN can be mapped to the host for reading and writing
- D. The snapshot LUN can only be mapped to the same host as the original LUN
Answer: C
NEW QUESTION 250
What is the correct description of the advantages of Huawei RAID 2.0+?
- A. There is no write penalty in RAID2.0+, which overcomes the write penalty in RAID 5 and RAID 6 levels in traditional RAID technology The impact of the penalty on the write performance of the LUN has greatly improved the performance of the LUN
- B. The data on a single LUN is distributed to many different hard disks, avoiding hard disk hot spots, making single LUN performance and The capacity has been greatly improved
- C. The data is automatically and evenly distributed on the hard disks in the storage pool to avoid uneven heating and cooling of the hard disk, thereby reducing the storage system Overall failure rate
- D. Overcome the performance bottleneck of the traditional RAID reconstruction target disk (hot spare disk), making the reconstruction bandwidth write bandwidth no longer It becomes the bottleneck of the reconstruction speed, which greatly improves the reconstruction speed, reduces the probability of double-disk failure, and improves the storage system.
Reliability.
Answer: A,B,C,D
NEW QUESTION 251
Which of the following allows direct physical access to end users?
- A. Clients.
- B. Network Switch.
- C. Storage Array.
- D. Backup System.
Answer: A
NEW QUESTION 252
IP SAN uses underlying optical networks to connect servers and storage systems.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 253
The multipath load balancing strategy used by Huawei OceanStor V3 storage products is the default?
- A. Polling
- B. the minimum task
- C. Minimum IO number
- D. Minimum queue depth
Answer: D
Explanation:
Explanation
Resolution: View product documentation.
NEW QUESTION 254
LAN Free and Server Free are backup networking methods that have little impact on host performance.
- A. TRUE
- B. FALSE
Answer: A
Explanation:
Explanation
Analysis: Both LAN Free and Server Free backup are based on SAN.
LAN Free backup, advantages: low server load, optimized data transmission efficiency; disadvantages: SAN layout fee High cost, equipment must be compatible with SAN Server Free backup, advantages: lowest server load, greatly optimized data transmission efficiency; disadvantages: SAN distribution The cost of installation is high, and the device must be compatible with the SAN, which requires third-party device support.
NEW QUESTION 255
HyperRepIication for HUAWEI OceanStor V3 can use FC links between the data centers. iSCSI links are not supported.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 256
It is a hard-disk failure that occurs when a read-write head of a hard disk drive comes in contact with its rotating platter, resulting in permanent and usually irreparable damage to the magnetic media on the platter surface. Which of the following fits the above description?
- A. Electrical Failure.
- B. Bad Sector.
- C. Head Crash.
- D. Bad Platter Area.
Answer: C
NEW QUESTION 257
Lifecycle Management Of Information and Data consists of 5 different stages. Which of the following is the second stage?
- A. Generation.
- B. Transmission.
- C. Usage.
- D. Maintenance.
Answer: B
NEW QUESTION 258
Is the following statement correct?
- A. OceanStor V3 series products support RAID 0/RAID 1/RAID 5/RAID 10, but not RAID 6
- B. NL SAS/SATA hard disks are suitable for data protection using RAID 6, and SAS hard disks are suitable for data protection using RAID 5.
According to protection
C, S2200 V3 can support SSD, SAS, SATA hard drives - C. After using RAID 5 with 6 200G hard drives, the available space is 1200G
Answer: B
Explanation:
Explanation
Resolution: The hard disk types supported by OceanStor 2200 V3 are: SAS, NL-SAS and SSD, and SATA is not supported. OceanStor V3 series product support
NEW QUESTION 259
The cloudification of IT architecture is from "separation" to "convergence". What does convergence mean?
- A. Integration of hardware and software
- B. Multi-application sharing and open "cloud computer"
- C. Application and server integration
- D. Convergence of IT infrastructure
Answer: B
NEW QUESTION 260
What is the correct description of RAID 5 as follows? (Multiple choice)
- A. RAID 5 is verified by XOR algorithm
- B. RAID 5 uses striping to write data
- C. RAID 5 has a fixed check disk
- D. RAID 5 allows up to two member disks to fail simultaneously without data loss
Answer: A,B
Explanation:
Explanation
Analysis: RAID 5 is an improved version of RAID 3 that uses striping and calculates parity information.
NEW QUESTION 261
Statement 1: Multipathing is caused by adding redundant hardware.
Statement 2: Huawei offers a different version of Ultra Path for different operating systems.
- A. Statement 1 is false and statement 2 is true.
- B. Statement 1 is true and statement 2 is false.
- C. Statements 1 and 2 are both true.
- D. Both statements 1 and 2 are false.
Answer: C
NEW QUESTION 262
HyperReplication for HUAWEI OceanStor V3 can use FC links the data centers. ISCSI links are not supported.
- A. TRUE
- B. FALSE
Answer: B
NEW QUESTION 263
What are the characteristics of big data? (Multiple choice)
- A. Large capacity and fast growth rate
- B. The value of data is uncertain
- C. Long storage time
- D. Write once, modify many times
Answer: A,B,C
NEW QUESTION 264
Storage controllers can be separated from the chassis of disk enclosures. It does not need to be integrated in design with the disk enclosures.
- A. TRUE
- B. FALSE
Answer: A
NEW QUESTION 265
Which of the following dimensions are often used to express the data used in Big Data scenarios? (Choose all that apply.)
- A. Variety
- B. Verticality
- C. Volume
- D. Velocity
Answer: A,C,D
NEW QUESTION 266
In a Red Hat Linux 5 operating system, which command is used to mount the sdb5 in the dev directory to the sdb5 in the mnt directory?
- A. df/dev/sdb5/mnt/sdb5
- B. cat /dev/sdb5 /mnt/sdb5
- C. In/dev/sdb5/mnt/sdb5
- D. mount /dev/sdb5 /mnt/sdb5
Answer: D
NEW QUESTION 267
......